Commit Graph
2 Commits
Author SHA1 Message Date
ARIA b8e91e3c91 fix: degrade gracefully when pyserial is missing
A stale venv after a code update (editable install + git pull) left
pyserial out of the environment, and the hard module-level import in
wireview.py took the entire web server down — even on machines without
a WireView device.

Guard the import: without pyserial the serial transport is disabled
(one-time warning, connect fails, reads return None) while the rest of
the server keeps running. The hwmon transport is unaffected.

Also simplify the except clauses to OSError (SerialException is an
OSError subclass) so they no longer reference the possibly-None module.
2026-10-03 13:32:43 +02:00
ARIA 526b71b45f feat: native WireView Pro II monitoring (detection, serial protocol, live tab)
Standalone support for the ThermalGrizzly WireView Pro II without
depending on the external wireview_reporter exporter:

- wireview.py: serial protocol (STX/ETX + 16-bit CRC16-CCITT) with
  vendor-data product identification, config version, UID, build
  string, screen layout, and temperature/power/current sensor reads;
  hwmon fallback with per-channel index resolution; udev-based
  detection (vendor 0x2560 / product 0x0101) with fallback port
  probing; serial read timeout and watchdog reconnect
- server.py: startup detection (root only), 1 Hz poller gated on
  subscribed clients, WS 'wireview' channel, GET /api/wireview,
  rejected-product memoization, stale-read race guard
- frontend: WireView tab (visible when a device is detected) with
  live temperature/power/current cards, sparkline history, and
  device info; nullable temp channels
- tests: 76 tests covering parser, CRC, fault classification,
  hwmon resolution, JSON safety, and the serial transport against
  a pty-based fake device

Verified live: tab appears with the device connected, disappears
when unplugged, reconnects on re-plug, no serial traffic when idle.
2026-10-03 13:20:56 +02:00