feat: wireview pin-imbalance warning, per-pin rating bars, pin_imbalance_a
- Per-pin bar now scales against the 9.2 A per-pin rating (10 A full scale, red at/over rating) instead of the 55 A total connector OCP - Debounced app-wide warning banner (visible on all tabs) when the current between two pins diverges by > 2 A for ~7 s - the signature of a bad pin contact that can overheat and melt the 12VHPWR connector; 5 s grace period after clearing - New pin_imbalance_a sample field (max - min pin current) in both the serial and hwmon sample builders, plus frontend type - Docs: README + WireView.md cover the warning and threshold; fresh screenshot with the new per-pin labels - Tests: vitest setup + 9 unit tests for the debounce state machine; 3 new backend checks for pin_imbalance_a
This commit is contained in:
1 parent
92356d1409
commit
b69b7502b3
14 files changed
+810
-18
No files matched your search
@@ -0,0 +1,8 @@
|
||||
import { defineConfig } from "vitest/config";
|
||||
|
||||
export default defineConfig({
|
||||
test: {
|
||||
environment: "happy-dom",
|
||||
include: ["src/**/*.test.ts"],
|
||||
},
|
||||
});
|
||||
Reference in new issue
Block a user